| Max. verwerkingsdruk | PN 100, klasse 600, 20K |
|---|---|
| Outputs | 4-20 mA HART (passief) |
| Digitale Mededeling | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Max. metingsfout | Volume stroom (standaard): ±0,5 % o.r. ± 1 mm/s (0,04 in/s) |
| Voeding | Gelijkstroom 12 tot 35 V |
| Product name | Radar measurement Micropilot FMR56 |
|---|---|
| Process pressure/max. overpressure limit | Vacuum...3 bar(Vacuum...43.5 psi) |
| Process connection | UNI DN80...DN150(3"...6") |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Measuring principle | Level radar solid |
| Wetted materials | 316L stainless steel, Alloy C, Tantalum (optional) |
|---|---|
| Output signal | 4 to 20 mA with HART |
| Applications | hygienic, chemical, and oil & gas applications |
| Process temperature(Standard) | -40 to +125 °C (-40 to +257 °F) |
| Packaging Details | Carton + Wooden Box + Protection |
| Omgevingstemperatuur | -50...+80 °C (-58...+176 °F) |
|---|---|
| Sensorlengte | Staafsonde: 10 m /Touwsonde: 45 m /Coaxiale sonde: 6 m |
| Mededeling | 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus |
| Procesdruk/max. overdruklimiet | Vacuüm...400 bar (vacuüm...5800 psi) |
| Het meten van principe | Geleide radar |
| Het meten van principe | Trillingsvloeistoffen |
|---|---|
| Omgevingstemperatuur | -50 °C...+70 °C (-58 °F...+158 °F) |
| Procestemperatuur | -50 °C+150 °C (-58 °F+302 °F) |
| Procesdruk/max. overdrukgrens | Vacuüm...100 bar |
| Min. dichtheid van middel | 0,5 g/cm³ (0,4 g/cm³ optioneel) |
| Nauwkeurigheid | ±0,5 % |
|---|---|
| Materiaal | Roestvrij staal |
| Meetbereik | 0,5 m3/u tot 263000 m3/u |
| Nominaal diameter bereik | DN 25 tot en met 3000 ((1 tot en met 120") |
| Max. verwerkingsdruk | PN 40, klasse 300, 20K |
| Medium temperature range | -40 to +150 °C (-40 to +302 °F) |
|---|---|
| accuracy | ±0.15 % |
| Measurement Range | 0 to 180 000 kg/h (0 to 6615 lb/min) |
| Medium | liquid, Gas |
| liquid, Gas | PN 100, Class 600, 63K |
| Product name | Radar measurement Micropilot FMR67 |
|---|---|
| Max. measurement distance | 125 m (410 ft) |
| Process temperature | -40...+200 °C(-40...+392 °F) |
| Measuring principle | Level radar solid |
| Communication | 4...20 mA HART |
| Nauwkeurigheid | ± 6 mm |
|---|---|
| Procestemperatuur | -60...+400°C (-76...+752°F) |
| Het meten van principe | Niveau radar |
| Omgevingstemperatuur | -50...+80 °C (-58...+176 °F) |
| Mededeling | 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus |
| Nauwkeurigheid | ± 6 mm |
|---|---|
| Procestemperatuur | -60...+400°C (-76...+752°F) |
| Het meten van principe | Niveau radar |
| Omgevingstemperatuur | -50...+80 °C (-58...+176 °F) |
| Mededeling | 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus |