Kenmerken
Specificaties
Materiaal: Roestvrij staal
Het meten van principe: Geleide radar
Procesdruk/max. overdruklimiet: Vacuüm...400 bar (vacuüm...5800 psi)
Mededeling: 4 ... 20 Ma Hart Profibus PA Foundation Fieldbus
Omgevingstemperatuur: -50...+80 °C (-58...+176 °F)
Sensorlengte: Staafsonde: 10 m /Touwsonde: 45 m /Coaxiale sonde: 6 m
Markeren:

Endress Hauser guided radar transmitter

,

FMP54 radar level measurement instrument

,

high accuracy guided wave radar

Basis informatie
Merknaam: Endress+Hauser
Modelnummer: FMP54
Betalen & Verzenden Algemene voorwaarden
Verpakking Details: Zoals vereist
Levertijd: 60 dagen
Betalingscondities: T/T
Levering vermogen: 1000 sets per jaar
Productomschrijving
Product Overview

In crude oil separators, desalters, alkali treaters and many chemical reactors you need both total level and the interface between two liquids. The FMP54 with coaxial probe does exactly that – one single instrument gives you reliable overall level AND the interface thickness, even when the upper layer is very thin or the emulsion band changes. No need for two separate devices. Plants love it because installation is simpler and spare parts inventory is lower.

Why It Works So Well for Interface
  • Coaxial probe forces the microwave through both layers – no reflection loss
  • Measures interface from 50 mm thickness upwards
  • Works even with heavy rag layer or emulsion
  • Built-in interface calculation in the transmitter
  • HART or FF output for both total level and interface
Key Numbers for Interface Service
Min. upper layer thickness 50 mm
Dielectric difference needed ≥ 2 between layers
Accuracy interface ±10 mm typical
Probe type Coaxial only for interface
Typical Interface Jobs
  • Crude oil production separators
  • Desalters and dehydrators
  • Acid-alkali treaters
  • Solvent extraction columns
Frequently Asked Questions

Q: Do I need a coaxial probe?
A: Yes – rope or rod versions can’t do reliable interface.

Q: What if the emulsion band is thick?
A: The transmitter shows the top of the emulsion as interface – exactly what operators want.

Contact Us

Email: edwardzhao@gbsxj.com

Phone/WhatsApp/WeChat: +8615000725058

Related Instruments
  • FMP51 coaxial for standard applications
  • FMR62 80 GHz radar for bigger tanks
  • Proservo NMS81 for custody transfer
Geadviseerde Producten
Neem contact op met ons
Contactpersoon : Mr. Edward Zhao
Tel. : +8615000725058
Resterend aantal tekens(20/3000)