Kenmerken
Specificaties
Bescherming tegen binnendringing: IP67
Stabiliteit: ± 0,125%
Uitvoer: 4-20 mA met digitaal signaal
Temperatuurbereik: -40 °C tot +85 °C
Protocollen: HART 5/6/7, FOUNDATION Fieldbus, PROFIBUS PA
Procesverbindingen: 1/2" NPT, geflensd, spruitstukopties
Basis informatie
Merknaam: Rosemount
Modelnummer: 3051DP /3051GP /3051TG /3051CD
Betalen & Verzenden Algemene voorwaarden
Verpakking Details: Zoals vereist
Levertijd: 60 dagen
Betalingscondities: T/T
Levering vermogen: 1000 sets per jaar
Productomschrijving
Rosemount 3051 Pressure Transmitter

The blue transmitter you see on pipes in every refinery, chemical plant and power station

Why Plants Keep Installing 3051s Even in 2025

Walk into any old plant and half the pressure transmitters are still 3051s from the 90s – they just keep working. New ones have the same coplanar design but better electronics, HART or Foundation Fieldbus, and local display. Instrument guys like them because the wiring is the same as the old ones, the calibration procedure hasn’t changed, and spare parts are everywhere. It measures pressure, level, flow – whatever you need.

Stuff That Hasn’t Changed Much (and That’s Good)
  • Coplanar flange – easy to mount, no leaks
  • Local zero and span buttons – adjust without handheld
  • Big LCD display on smart versions
  • 4–20 mA HART – talks to every DCS
  • Stainless diaphragm – handles almost anything
  • Works from -40 °C to +120 °C without drama
Basic Numbers
Types Gage, absolute, differential, level
Ranges From inches water to 10,000 psi
Accuracy ±0.04% of span (best versions)
Output 4–20 mA HART, Foundation Fieldbus
Materials 316L SST, Hastelloy, Tantalum
Approvals ATEX, FM, CSA, SIL 2/3
Where They Live
  • Process lines in refineries
  • Boiler drum level
  • Tank level and interface
  • Flow with orifice plates
Questions We Get Every Day

Q: Do you still make the 3051?
A: Yes – new units ship every day from Chanhassen.

Q: Can I replace my old 1151?
A: Yes – same manifold holes, same wiring.

Contact

Emerson Rosemount
Phone: +8615000725058
Email: edwardzhao@gbsxj.com

Other Transmitters
  • 3051S – advanced version with diagnostics
  • 2051 – lower cost basic one
  • 3051CFA Annubar flowmeter