Specificaties
Feedback: Met feedback
Leveringsmedia: Luchtoliegas
Modelnummer: Fisher DVC6200
Herhaalbaarheid: ≤0,25%
Subtype: Digitaal
Productnaam: Digitale kleppositieer
Temperatuur: -40 ° +85 °
Kleur: Grijs
Basis informatie
Plaats van herkomst: China/Singapore
Merknaam: Fish-er
Modelnummer: DVC6200
Betalen & Verzenden Algemene voorwaarden
Verpakking Details: 50x50x30 cm
Levertijd: 5 dagen
Betalingscondities: 100% vooraf
Levering vermogen: 30PCS in Voorraad
Productomschrijving
Product Overview

The Fish-er FIELDVUE DVC6200 is a high-performance digital valve controller that converts a 4-20 mA control signal into pneumatic output for accurate valve positioning. It supports HART communication for setup, monitoring, and diagnostics, helping operations stay closer to setpoint for better process control and product quality. Available in aluminum or stainless steel, it works with single- or double-acting actuators in linear or rotary applications.

Features
  • Linkageless feedback using contactless Hall-Effect technology with stem/shaft-mounted magnet array for reliable, low-maintenance positioning.
  • Advanced diagnostics via ValveLink software or AMS, including travel history, pressure readings, and valve performance insights.
  • One-button setup and calibration for quick commissioning.
  • Low air consumption with optional low-bleed relay to reduce operating costs.
  • Integral pressure sensors for real-time monitoring of supply, output, and actuator pressures.
  • SIL 3 capable (HART version when input is 0 mA/0 VDC) for safety-critical uses.
  • Modular design with options for hazardous area certifications.
Technical Specifications
Communication Protocol 4-20 mA HART (HART 5 or HART 7 selectable)
Input Signal 4-20 mA DC, nominal; minimum voltage 9.5 V DC for analog control, 10 V DC for HART
Supply Pressure Minimum recommended 0.3 bar / 5 psig above actuator requirements; maximum 10.0 bar / 145 psig
Output Signal Pneumatic up to full supply pressure; minimum span 0.4 bar / 6 psig, maximum span 9.5 bar / 140 psig
Steady-State Air Consumption (standard relay) <0.38 Nm³/h / 14 scfh at 1.4 bar / 20 psig; <1.3 Nm³/h / 49 scfh at 5.5 bar / 80 psig
Low Bleed Relay Average 0.056 Nm³/h / 2.1 scfh at 1.4 bar; 0.184 Nm³/h / 6.9 scfh at 5.5 bar
Maximum Output Capacity 10.0 Nm³/h / 375 scfh at 1.4 bar; 29.5 Nm³/h / 1100 scfh at 5.5 bar
Operating Temperature -40 to +85 °C / -40 to +185 °F (standard); -52 to +85 °C / -62 to +185 °F with fluorosilicone elastomers
Enclosure Protection IP66/Type 4X
Housing Materials Low-copper aluminum (standard) or stainless steel (optional)
Mounting Integral to Fish-er 657/667/GX actuators; compliant with IEC 60534-6-1/-6-2, VDI/VDE 3845, NAMUR; remote-mount options available
Certifications Explosion Proof, Intrinsically Safe, Non-incendive, Flame Proof (CSA, FM, ATEX, IECEx)
Applications

Widely used for control valve positioning in oil & gas, refining, chemical processing, power generation, and pulp & paper industries—especially where diagnostics help reduce unplanned downtime and improve loop performance.

FAQ
Q: How does it handle diagnostics?
A: It uses built-in pressure sensors and travel data for predictive insights via ValveLink or AMS software.
Q: Is linkage required?
A: No—linkageless design uses magnetic feedback for most setups.
Q: What about air usage?
A: Standard relay is low consumption; low-bleed option further reduces it for efficiency.
Q: Can it be used in hazardous areas?
A: Yes, with approvals for explosion-proof, intrinsically safe, and other classifications.
Q: What's the temperature range?
A: -40 to +85 °C standard; down to -52 °C with extreme temperature elastomers.
Contact Us

Email: tracychen@gbsxj.com

WhatsApp: +8617799852698

Phone/wechat: 13032169170

Related Products

Consider the DVC6200 SIS for safety instrumented systems, or the DVC6200f/P for FOUNDATION fieldbus/PROFIBUS PA protocols.

Beoordelingen & Recensies

Algemene Beoordeling

5.0
Gebaseerd op 50 beoordelingen voor deze leverancier

Ratingsnapshot

Het volgende is de verdeling van alle beoordelingen
5 sterren
100%
4 sterren
0%
3 sterren
0%
2 sterren
0%
1 sterren
0%

Alle recensies

A
Annie Dowson
United Kingdom Jan 8.2026
The Emerson AMS Trex we received is top quality – solid build, responsive touchscreen, and works perfectly with our HART and Fieldbus devices. It’s definitely made our commissioning and troubleshooting a lot more efficient. Also, big thanks to the seller – very professional, fast shipping, and they knew exactly what we needed. Super reliable supplier. Would absolutely buy from them again.
Geadviseerde Producten
Neem contact op met ons
Contactpersoon : Mr. Edward Zhao
Tel. : +8615000725058
Resterend aantal tekens(20/3000)